What do you want to know?

Overview of benefits

Minimal appliance width for easy handling through 800-mm doorways

Extremely clean combustion, high standard seasonal efficiency up to 110% (net cv) / 99% (gross cv) for the best possible energy efficiency

Modulating output control from 17 - 100%

Neutralising system set with booster and condensate removal pump can be integrated into the casing

Can be combined with BM-2 programming unit or AM display module

Integrated spread control for optimised utilisation of the boiler’s condensing effect and minimal power consumption by the boiler circuit pump

Slots for pallet truck or forklift forks for easier handling

All maintenance tasks can be performed from the front and right. The boiler can therefore be positioned with the back and left sides directly against the wall

Heat exchanger made from proven aluminium-silicon alloy

Appliance fully thermally insulated

Cascades with up to 5 gas condensing boilers

Integrated back draught safety device for cascade operation

Does not require return flow heating or a minimum water circulation volume

Quick, easy installation thanks to prefitted casing; fully prepared for direct connection to power and water supply

Communication with 0-10V input for optional integration into BMS systems via smartphone, laptop or PC using WOLF Link home LAN/WiFi module

Specifications

MGK-2 130-300
Model type
MGK-2-130
MGK-2-170
MGK-2-210
MGK-2-250
MGK-2-300
General data
Rated heating output at 80/60°C
kW
118
157
196
233
275
Rated heating output at 50/30°C
kW
126
167
208
250
294
Rated heat input
kW
120
160
200
240
280
Lowest heating output (modulating) at 80/60°C
kW
23
27
34
39
45
Lowest heating output (modulating) at 50/30°C
kW
24
30
37
44
49
Lowest heat input (modulating)
kW
23
28
35
41
46
Heat input modulation range
%
19-100
17-100
17-100
17-100
17-100
Amount of condensate at 40/30°C
l/h
12
16
20
24
28
Condensate pH value
approx. 4.0
approx. 4.0
approx. 4.0
approx. 4.0
approx. 4.0
Gas connection
R
1“
1½“
1½“
1½“
1½“
Balanced flue
Type
B23(P), B33, C33(x), C43(x), C53(x), C63(x), C83, C93(x)
Efficiency
η 80/60 at Qmax
%
98.1
98
98.1
98
98
η 50/30 at Qmax
%
104.1
104.2
104.3
103.9
105.2
η TR30 at 30%
%
107.8
106.9
106.7
106.6
106.8
Dimensions
Height
A mm
1300
1300
1300
1300
1300
Width
B mm
995
1355
1355
1355
1355
Depth
C mm
640
640
640
640
640
Flue diameter
mm
160
160
160
160
200
Combustion air supply 4)
mm
160
160
160
160
160
Heating flow line outside diameter
R
1½“
2“
2“
2“
2“
Heating return line outside diameter
R
2“
2“
2“
2“
Gas category
Germany
II2ELL3P
II2ELL3P
II2ELL3P
II2ELL3P
II2ELL3P
Austria
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
Switzerland
I2H
I2H
I2H
I2H
I2H
Gas connection value:
Natural gas E/H (net cv = 9.5 kWh/m³ = 34.2 MJ/m³)
m³/h
13.1
16.8
21
25.2
29.4
Natural gas LL (net cv = 8.6 kWh/m³ = 31.0 MJ/m³) 1)
m³/h
14.6
18.6
23.3
27.9
32.6
LPG P (net cv = 12.8 kWh/kg = 46.1 MJ/kg) 2)
kg/h
9.6
12.5
15.6
18.7
21.8
Gas supply pressure:
Natural gas E/LL
mbar
20
20
20
20
20
LPG P
mbar
50
50
50
50
50
Water capacity of the heating water heat exchanger
litres
12
15.4
16
20
22
Max. permissible boiler pressure
bar
6
6
6
6
6
Max. permissible flow temperature
°C
90
90
90
90
90
Available gas fan draught
Pa
10-200
10-150
10-150
10-150
10-150
Flue gas temperature 80/60-50/30 at Qmax
°C
65-45
65-45
65-45
65-45
65-45
Flue gas temperature 80/60-50/30 at Qmin
°C
55-35
55-35
55-35
55-35
55-35
Max. flue gas mass flow rate
g/s
56.7
72.5
90.8
108.9
127.1
Flue gas category to DVGW G 635
G52
G52
G52
G52
G52
Heating water pressure drop with 20 K spread
mbar
95
100
115
135
160
Electrical connection
V~/Hz
1~ NPE / 230 V AC / 50 Hz
Integral fuse (medium time lag)
A
4
4
4
4
4
Standby power consumption
W
5
5
5
5
5
Power consumption at partial load/full load
W
30 / 240
42 / 258
42 / 291
43 / 326
48 / 350
IP rating
IP20
IP20
IP20
IP20
IP20
Sound pressure level at full load 3)
dB(A)
~ 49
~ 54
~ 54
~ 54
~ 54
Weight
Total weight (empty)
kg
195
250
271
292
313

Specifications

MGK-2 130-300
  • MGK-2-130

  • MGK-2-170

  • MGK-2-210

  • MGK-2-250

  • MGK-2-300

    General data
    Rated heating output at 80/60°C (kW)
    118
    157
    196
    233
    275
    Rated heating output at 50/30°C (kW)
    126
    167
    208
    250
    294
    Rated heat input (kW)
    120
    160
    200
    240
    280
    Lowest heating output (modulating) at 80/60°C (kW)
    23
    27
    34
    39
    45
    Lowest heating output (modulating) at 50/30°C (kW)
    24
    30
    37
    44
    49
    Lowest heat input (modulating) (kW)
    23
    28
    35
    41
    46
    Heat input modulation range (%)
    19-100
    17-100
    17-100
    17-100
    17-100
    Amount of condensate at 40/30°C (l/h)
    12
    16
    20
    24
    28
    Condensate pH value
    approx. 4.0
    approx. 4.0
    approx. 4.0
    approx. 4.0
    approx. 4.0
    Gas connection (R)
    1“
    1½“
    1½“
    1½“
    1½“
    Balanced flue (Type)
    B23(P), B33, C33(x), C43(x), C53(x), C63(x), C83, C93(x)
    Efficiency
    η 80/60 at Qmax (%)
    98.1
    98
    98.1
    98
    98
    η 50/30 at Qmax (%)
    104.1
    104.2
    104.3
    103.9
    105.2
    η TR30 at 30% (%)
    107.8
    106.9
    106.7
    106.6
    106.8
    Dimensions
    Height (A mm)
    1300
    1300
    1300
    1300
    1300
    Width (B mm)
    995
    1355
    1355
    1355
    1355
    Depth (C mm)
    640
    640
    640
    640
    640
    Flue diameter (mm)
    160
    160
    160
    160
    200
    Combustion air supply 4) (mm)
    160
    160
    160
    160
    160
    Heating flow line outside diameter (R)
    1½“
    2“
    2“
    2“
    2“
    Heating return line outside diameter (R)
    2“
    2“
    2“
    2“
    Gas category
    Germany
    II2ELL3P
    II2ELL3P
    II2ELL3P
    II2ELL3P
    II2ELL3P
    Austria
    II2H3P
    II2H3P
    II2H3P
    II2H3P
    II2H3P
    Switzerland
    I2H
    I2H
    I2H
    I2H
    I2H
    Gas connection value:
    Natural gas E/H (net cv = 9.5 kWh/m³ = 34.2 MJ/m³) (m³/h)
    13.1
    16.8
    21
    25.2
    29.4
    Natural gas LL (net cv = 8.6 kWh/m³ = 31.0 MJ/m³) 1) (m³/h)
    14.6
    18.6
    23.3
    27.9
    32.6
    LPG P (net cv = 12.8 kWh/kg = 46.1 MJ/kg) 2) (kg/h)
    9.6
    12.5
    15.6
    18.7
    21.8
    Gas supply pressure:
    Natural gas E/LL (mbar)
    20
    20
    20
    20
    20
    LPG P (mbar)
    50
    50
    50
    50
    50
    Water capacity of the heating water heat exchanger (litres)
    12
    15.4
    16
    20
    22
    Max. permissible boiler pressure (bar)
    6
    6
    6
    6
    6
    Max. permissible flow temperature (°C)
    90
    90
    90
    90
    90
    Available gas fan draught (Pa)
    10-200
    10-150
    10-150
    10-150
    10-150
    Flue gas temperature 80/60-50/30 at Qmax (°C)
    65-45
    65-45
    65-45
    65-45
    65-45
    Flue gas temperature 80/60-50/30 at Qmin (°C)
    55-35
    55-35
    55-35
    55-35
    55-35
    Max. flue gas mass flow rate (g/s)
    56.7
    72.5
    90.8
    108.9
    127.1
    Flue gas category to DVGW G 635
    G52
    G52
    G52
    G52
    G52
    Heating water pressure drop with 20 K spread (mbar)
    95
    100
    115
    135
    160
    Electrical connection (V~/Hz)
    1~ NPE / 230 V AC / 50 Hz
    Integral fuse (medium time lag) (A)
    4
    4
    4
    4
    4
    Standby power consumption (W)
    5
    5
    5
    5
    5
    Power consumption at partial load/full load (W)
    30 / 240
    42 / 258
    42 / 291
    43 / 326
    48 / 350
    IP rating
    IP20
    IP20
    IP20
    IP20
    IP20
    Sound pressure level at full load 3) (dB(A))
    ~ 49
    ~ 54
    ~ 54
    ~ 54
    ~ 54
    Weight
    Total weight (empty) (kg)
    195
    250
    271
    292
    313