What do you want to know?

Overview of benefits

The WOLF residential ventilation unit designed for comfort provides convenient, energy-saving ventilation all year round.

Suitable for apartments, detached houses and apartment buildings as well as offices.

Using the cross- and countercurrent heat exchanger, heat is withdrawn from the extract air and transferred to the fresh supply air.

Compact design, for wall mounting

Clean, pollen-free fresh air - ventilation with your windows closed, cutting out street noise (not only for allergy sufferers)

Removable plastic cross-countercurrent plate heat exchanger

Bypass as standard

Automatic frost stat control

Constant flow fans

Low energy consumption thanks to DC fans

BM-2 for operation (optional)

Electr. 1000-W preheating coil integrated in the appliance

Filter category ISO coarse 60% / ISO ePM1 50% as optional accessory

Unit fully wired.

Filter change requirement indicated on the appliance, programming unit or 4-step switch

DIBt approval and passive house certificate

Specifications

Model type
CWL-300 Excellent
CWL-400 Excellent
Energy efficiency class
A
A
Max. air handling rate at 150 Pa
m³/h
300
400
Max. heat provision efficiency
%
89
93
Height
mm
765
765
Width
mm
677
677
Depth
mm
564
564
Duct connection diameter
mm
160
180
Filter category
ISO coarse 60% (ISO ePM1 50% as accessory)
ISO coarse 60% (ISO ePM1 50% as accessory)
Power factor
Cos φ
0.37 - 0.51
0.38 - 0.61
Power consumption
W
3 - 138
3 - 172
Power consumption
W
58 (at 225 m³/h and 100 Pa)
84 (at 300 m³/h and 100 Pa)
(without preheating coil)
Weight
kg
38
38
IP rating
IP
30
30
Electrical connection
230 V / 50 Hz
230 V / 50 Hz

Specifications

Energy efficiency class
A
A
Max. air handling rate at 150 Pa (m³/h)
300
400
Max. heat provision efficiency (%)
89
93
Height (mm)
765
765
Width (mm)
677
677
Depth (mm)
564
564
Duct connection diameter (mm)
160
180
Filter category
ISO coarse 60% (ISO ePM1 50% as accessory)
ISO coarse 60% (ISO ePM1 50% as accessory)
Power factor (Cos φ)
0.37 - 0.51
0.38 - 0.61
Power consumption (W)
3 - 138
3 - 172
Power consumption (W)
58 (at 225 m³/h and 100 Pa)
84 (at 300 m³/h and 100 Pa)
(without preheating coil)
Weight (kg)
38
38
IP rating (IP)
30
30
Electrical connection
230 V / 50 Hz
230 V / 50 Hz